Commercial Refrigerators
Marginal note:Energy-using product
637 (1) A commercial refrigerator is prescribed as an energy-using product.
Marginal note:Limits
(2) However, a commercial refrigerator is not considered to be an energy-using product
(a) for the purposes of sections 4 and 5, unless
(i) it is self-contained and manufactured on or after April 1, 2007, or
(ii) it is remote-condensing and manufactured on or after January 1, 2012; and
(b) for the purpose of section 638, unless
(i) it is self-contained, closed and was manufactured on or after April 1, 2007 and before January 1, 2012, or
(ii) it is manufactured on or after January 1, 2012.
Marginal note:Energy efficiency standards
638 (1) The energy efficiency standards set out in column 3 of the table to this section apply to commercial refrigerators described in column 1 that are manufactured during the periods set out in column 4.
Marginal note:Testing standard
(2) A commercial refrigerator complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a commercial refrigerator as defined in section 636.
Column 1 Column 2 Column 3 Column 4 Item Energy-using Product Testing Standard Energy Efficiency Standard Period of Manufacture 1 Commercial refrigerators that are self-contained, closed and not transparent CSA C657, Test Procedure A Edaily ≤ 0.00441 V + 4.22 On or after April 1, 2007 and before January 1, 2008 2 Commercial refrigerators that are self-contained, closed and not transparent CSA C657, Test Procedure A Edaily ≤ 0.00441 V + 2.76 On or after January 1, 2008 and before January 1, 2010 3 Commercial refrigerators that are self-contained, closed and not transparent CSA C657, Test Procedure A Edaily ≤ 0.00353 V + 2.04 On or after January 1, 2010 and before March 27, 2017 4 Commercial refrigerators that are self-contained and transparent CSA C657, Test Procedure A Edaily ≤ 0.00607 V + 5.78 On or after April 1, 2007 and before January 1, 2008 5 Commercial refrigerators that are self-contained and transparent CSA C657, Test Procedure A Edaily ≤ 0.00607 V + 4.77 On or after January 1, 2008 and before January 1, 2010 6 Commercial refrigerators that are self-contained and transparent and that do not have pull-down temperature reduction capability CSA C657, Test Procedure A Edaily ≤ 0.00424 V + 3.34 On or after January 1, 2010 and before March 27, 2017 7 Commercial refrigerators that are self-contained and transparent and that have pull-down temperature reduction capability CSA C657, Test Procedure A Edaily ≤ 0.00445 V + 3.51 On or after January 1, 2010 and before March 27, 2017 8 Commercial refrigerators that are self-contained and open CSA C657, Test Procedure A CSA C657, Table 5 On or after January 1, 2012 and before March 27, 2017 9 Commercial refrigerators that are remote-condensing CSA C657, Test Procedure A CSA C657, Table 5 On or after January 1, 2012 and before March 27, 2017 10 Commercial refrigerators CSA C657, Test Procedure B CSA C657, Table 6 On or after March 27, 2017
Marginal note:Information
639 (1) For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a commercial refrigerator:
(a) its Edaily;
(b) for each of its compartments,
(i) its equipment class designation and its TDA or V, as applicable, and
(ii) if it is tested at its lowest temperature setting, the integrated average temperature, expressed in degrees Celsius, at the lowest temperature setting.
Marginal note:Standards
(2) The information must be collected in accordance with one of the following standards:
(a) CSA C657, Test Procedure A, if the product was manufactured before March 27, 2017; or
(b) CSA C657, Test Procedure B, if the product is manufactured on or after March 27, 2017.
Commercial Refrigerator-Freezers
Marginal note:Energy-using product
640 (1) A commercial refrigerator-freezer is prescribed as an energy-using product.
Marginal note:Limits
(2) However, a commercial refrigerator-freezer is not considered to be an energy-using product
(a) for the purposes of sections 4 and 5, unless
(i) it is self-contained, is closed and is manufactured on or after April 1, 2007,
(ii) it is self-contained, is open and is manufactured on or after January 1, 2012, or
(iii) it is remote-condensing and is manufactured on or after January 1, 2012; and
(b) for the purpose of section 641, unless
(i) it is self-contained, is closed, is not transparent and is manufactured on or after April 1, 2007,
(ii) it is self-contained, is open or transparent and is manufactured on or after January 1, 2012, or
(iii) it is remote-condensing and is manufactured on or after January 1, 2012.
Marginal note:Energy efficiency standards
641 (1) The energy efficiency standards set out in column 3 of the table to this section apply to commercial refrigerator-freezers described in column 1 that are manufactured during the periods set out in column 4.
Marginal note:Testing standard
(2) A commercial refrigerator-freezer complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a commercial refrigerator-freezer as defined in section 636.
Column 1 Column 2 Column 3 Column 4 Item Energy-using Product Testing Standard Energy Efficiency Standard Period of Manufacture 1 Commercial refrigerator-freezers that are self-contained, closed and not transparent CSA C657, Test Procedure A Edaily ≤ 0.00964 AV + 2.63 On or after April 1, 2007 and before January 1, 2008 2 Commercial refrigerator-freezers that are self-contained, closed and not transparent CSA C657, Test Procedure A Edaily ≤ 0.00964 AV + 1.65 On or after January 1, 2008 and before January 1, 2010 3 Commercial refrigerator-freezers that are self-contained, closed and not transparent CSA C657, Test Procedure A Edaily ≤ the greater of (0.00953 AV – 0.71) and 0.70 On or after January 1, 2010 and before March 27, 2017 4 Commercial refrigerator-freezers that are self-contained and open or transparent CSA C657, Test Procedure A CSA C657, Table 5 On or after January 1, 2012 and before March 27, 2017 5 Commercial refrigerator-freezers that are remote-condensing CSA C657, Test Procedure A CSA C657, Table 5 On or after January 1, 2012 and before March 27, 2017 6 Commercial refrigerator-freezers CSA C657, Test Procedure B CSA C657, Table 6 On or after March 27, 2017
Marginal note:Information
642 For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of a commercial refrigerator-freezer described in column 1.
Column 1 | Column 2 | Column 3 | |
---|---|---|---|
Item | Energy-using Product | Testing Standard | Information |
1 | Commercial refrigerator-freezers that are self-contained, closed, not transparent and manufactured on or after April 1, 2007 and before March 27, 2017 | CSA C657, Test Procedure A |
|
2 | Commercial refrigerator-freezers that are self-contained, transparent and manufactured on or after April 1, 2007 and before January 1, 2012 | CSA C657, Test Procedure A |
|
3 | Commercial refrigerator-freezers that are self-contained, open or transparent and manufactured on or after January 1, 2012 and before March 27, 2017 | CSA C657, Test Procedure A |
|
4 | Commercial refrigerator-freezers that are remote-condensing and manufactured on or after January 1, 2012 and before March 27, 2017 | CSA C657, Test Procedure A |
|
5 | Commercial refrigerator-freezers that are manufactured on or after March 27, 2017 | CSA C657, Test Procedure B |
|
- Date modified: