Language selection

Government of Canada

Search

Energy Efficiency Regulations, 2016

Version of section 134 from 2025-10-09 to 2026-02-18:


Marginal note:Energy efficiency standards — single-phase

  •  (1) The energy efficiency standards set out in column 3 of Table 1 to this section apply to single-phase split system central air conditioners described in column 1 that are manufactured during the periods set out in column 4.

  • Marginal note:Energy efficiency standards — three-phase

    (1.1) The energy efficiency standards set out in column 3 of Table 2 to this section apply to three-phase split system central air conditioners described in column 1 that are manufactured during the periods set out in column 4.

  • Marginal note:Testing standard

    (2) A split system central air conditioner complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a split system central air conditioner as defined in section 132.

    TABLE 1

    Column 1Column 2Column 3Column 4
    ItemEnergy-using ProductTesting StandardEnergy Efficiency StandardPeriod of Manufacture
    1Split system central air conditioners, other than those that are small-duct and high-velocity

    CSA C656-14 for seasonal energy efficiency ratio

    10 C.F.R. Appendix M for off mode power consumption

    Seasonal energy efficiency ratio ≥ 13.0

    Off mode power consumption ≤ 30 W

    On or after February 3, 1995 and before January 1, 2023
    2Split system central air conditioners that are small-duct and high-velocity

    CSA C656-14 for seasonal energy efficiency ratio

    10 C.F.R. Appendix M for off mode power consumption

    Seasonal energy efficiency ratio ≥ 12.0

    Off mode power consumption ≤ 30 W

    On or after February 3, 1995 and before January 1, 2023
    3Split system central air conditioners, other than those that are space-constrained or small-duct and high-velocity10 C.F.R. Appendix M1

    Seasonal energy efficiency ratio 2 ≥ 13.4

    Off mode power consumption ≤ 30 W

    On or after January 1, 2023
    4Split system central air conditioners that are small-duct and high-velocity10 C.F.R. Appendix M1

    Seasonal energy efficiency ratio 2 ≥ 12.0

    Off mode power consumption ≤ 30 W

    On or after January 1, 2023
    5Split system central air conditioners that are space-constrained10 C.F.R. Appendix M1

    Seasonal energy efficiency ratio 2 ≥ 11.7

    Off mode power consumption ≤ 30 W

    On or after January 1, 2023

    TABLE 2

    Column 1Column 2Column 3Column 4
    ItemEnergy-using ProductTesting StandardEnergy Efficiency StandardPeriod of Manufacture
    1Split system central air conditioners, other than those that are small-duct and high-velocityCSA C656-14Seasonal energy efficiency ratio ≥ 13.0On or after February 3, 1995 and before January 1, 2026
    2Split system central air conditioners, other than those that are space-constrained or small-duct and high-velocity10 C.F.R. Appendix F1Seasonal energy efficiency ratio 2 ≥ 13.4On or after January 1, 2026
    3Split system central air conditioners that are small-duct and high-velocityCSA C656-14Seasonal energy efficiency ratio ≥ 12.0On or after February 3, 1995 and before January 1, 2026
    4Split system central air conditioners that are small-duct and high-velocity10 C.F.R. Appendix F1Seasonal energy efficiency ratio 2 ≥ 13.0On or after January 1, 2026
    5Split system central air conditioners that are space-constrained10 C.F.R. Appendix F1Seasonal energy efficiency ratio 2 ≥ 12.7On or after January 1, 2026
  • SOR/2019-163, s. 25
  • SOR/2022-265, s. 10
  • SOR/2025-110, s. 20(E)
  • SOR/2025-110, s. 21

Page Details