Energy Efficiency Regulations, 2016
Marginal note:Energy efficiency standards — single-phase
134 (1) The energy efficiency standards set out in column 3 of Table 1 to this section apply to single-phase split system central air conditioners described in column 1 that are manufactured during the periods set out in column 4.
Marginal note:Energy efficiency standards — three-phase
(1.1) The energy efficiency standards set out in column 3 of Table 2 to this section apply to three-phase split system central air conditioners described in column 1 that are manufactured during the periods set out in column 4.
Marginal note:Testing standard
(2) A split system central air conditioner complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a split system central air conditioner as defined in section 132.
TABLE 1
Column 1 Column 2 Column 3 Column 4 Item Energy-using Product Testing Standard Energy Efficiency Standard Period of Manufacture 1 Split system central air conditioners, other than those that are small-duct and high-velocity CSA C656-14 for seasonal energy efficiency ratio
10 C.F.R. Appendix M for off mode power consumption
Seasonal energy efficiency ratio ≥ 13.0
Off mode power consumption ≤ 30 W
On or after February 3, 1995 and before January 1, 2023 2 Split system central air conditioners that are small-duct and high-velocity CSA C656-14 for seasonal energy efficiency ratio
10 C.F.R. Appendix M for off mode power consumption
Seasonal energy efficiency ratio ≥ 12.0
Off mode power consumption ≤ 30 W
On or after February 3, 1995 and before January 1, 2023 3 Split system central air conditioners, other than those that are space-constrained or small-duct and high-velocity 10 C.F.R. Appendix M1 Seasonal energy efficiency ratio 2 ≥ 13.4
Off mode power consumption ≤ 30 W
On or after January 1, 2023 4 Split system central air conditioners that are small-duct and high-velocity 10 C.F.R. Appendix M1 Seasonal energy efficiency ratio 2 ≥ 12.0
Off mode power consumption ≤ 30 W
On or after January 1, 2023 5 Split system central air conditioners that are space-constrained 10 C.F.R. Appendix M1 Seasonal energy efficiency ratio 2 ≥ 11.7
Off mode power consumption ≤ 30 W
On or after January 1, 2023 TABLE 2
Column 1 Column 2 Column 3 Column 4 Item Energy-using Product Testing Standard Energy Efficiency Standard Period of Manufacture 1 Split system central air conditioners, other than those that are small-duct and high-velocity CSA C656-14 Seasonal energy efficiency ratio ≥ 13.0 On or after February 3, 1995 and before January 1, 2026 2 Split system central air conditioners, other than those that are space-constrained or small-duct and high-velocity 10 C.F.R. Appendix F1 Seasonal energy efficiency ratio 2 ≥ 13.4 On or after January 1, 2026 3 Split system central air conditioners that are small-duct and high-velocity CSA C656-14 Seasonal energy efficiency ratio ≥ 12.0 On or after February 3, 1995 and before January 1, 2026 4 Split system central air conditioners that are small-duct and high-velocity 10 C.F.R. Appendix F1 Seasonal energy efficiency ratio 2 ≥ 13.0 On or after January 1, 2026 5 Split system central air conditioners that are space-constrained 10 C.F.R. Appendix F1 Seasonal energy efficiency ratio 2 ≥ 12.7 On or after January 1, 2026
- SOR/2019-163, s. 25
- SOR/2022-265, s. 10
- SOR/2025-110, s. 20(E)
- SOR/2025-110, s. 21
Page Details